Search results for " power system measurements"
showing 10 items of 16 documents
Un approccio semplificato per il calcolo del load flow nelle smart grids basato su misure distribuite in bassa tensione
2017
I sistemi di misura distribuiti sono alla base delle "smart distribution grids", ove la crescente presenza di generazione distribuita e sistemi di accumulo e la conseguente transizione verso sistemi attivi rendono necessarie funzionalità avanzate di monitoraggio, controllo e gestione delle reti. In tale contesto, un elemento essenziale è l'analisi dei flussi di potenza, che, com'è noto, può essere effettuata tramite algoritmi di load flow, noti il modello della rete e le potenze generate/assorbite nei vari nodi. Per la misura di tali grandezze sulla media tensione (MT), si possono utilizzare diversi strumenti (quali phasor measurement units, smart meters, power quality analyzers), che però …
A new low cost power line communication solution for smart grid monitoring and management
2018
Modern smart grids require the improvement of measurement and communication infrastructures of distribution networks, at both medium voltage (MV) and low voltage (LV) levels. Distributed sensing and measurement systems are needed to provide all necessary data for grid monitoring, control and management, as well as for the implementation of a number of smart functionalities, such as remote control of distributed generators (DGs), real time analysis of power flows, automatic meter reading (AMR), demand side management (DSM), grid automation and so on [1]-[6]. Acquired network data include typical electrical network quantities and status variables (such as powers, voltages, currents, switches …
LV Measurement Device Placement for Load Flow Analysis in MV Smart Grids
2016
This paper deals with the issue of measurement device placement for load flow analysis in medium-voltage (MV) distribution networks. The study is carried out using an innovative measurement algorithm for load flow analysis developed by the authors. It is based on low-voltage (LV) load power measurements applied on a backward/forward algorithm for the load flow resolution. The final aim is to identify the most suitable number and placement of the LV measurement points in order to limit the uncertainty on the power flow estimation to a target value. The proposed approach is based on the uncertainty evaluation of the estimated power flows; a sensitivity analysis is performed in order to assess…
An Innovative Measurement Approach for Load Flow Analysis in MV Smart Grids
2016
This paper proposes a novel measurement procedure for load flow analysis in medium voltage (MV) smart grids. The new approach is based on power measurements at low voltage (LV) side of MV/LV distribution substations. Such measurements are carried out by means of power quality analyzers. If compared with the load flow methods based on measurements at the MV side, the proposed approach has a lower cost and it offers an equally reliable measurement system. The proposed algorithm takes the basic concept of the current summation backward/forward method; some modifications are introduced to use LV load powers measurements. To this aim, the MV/LV power transformer is properly modeled and taken int…
A New Low Cost Coupling System for Power Line Communication on Medium Voltage Smart Grids
2018
This paper proposes and verifies the performance of an innovative and low cost coupling system for power line communication (PLC) on medium voltage (MV) smart grids. The coupling system makes use of the capacitive divider of the voltage detecting systems (VDSs) to inject and receive the PLC signal. VDS are usually already installed in the MV switchboards of the major electrical manufacturer all over the world according to IEC 61243-5. VDS are used to detect the presence of the mains voltage to guarantee personnel safety. An interface circuit has been developed to be connected between the PLC transceiver and the VDS socket. In this way, the PLC signal can be coupled to the MV network without…
Synchronization techniques for power quality instruments
2004
The measurement of voltage characteristics in power systems requires the accurate estimation of the power supply frequency and signal synchronization, even in the presence of disturbances. The authors developed and tested two innovative techniques for instrument synchronization. The first is based on signal spectral analysis techniques performed by means of the Chirp-Z transform analysis. The second is a phase-locked loop (PLL) software based on a time-domain coordinate transformation and an innovative phase-detection technique. To evaluate how synchronization techniques are adversely affected by the application of a disturbing influence, experimental tests were carried out, taking into acc…
New Measurement Procedure for Load Flow Evaluation in Medium Voltage Smart Grids
2013
The aim of this paper is to present a new approach for the medium voltage (MV) distribution network load flow analysis, mainly based on power measurement at the low voltage (LV) level of MV/LV distribution substations. This allows to use measurement instruments, usually already installed in the secondary substations, thus achieving an equally reliable measurement system with a lower cost compared to measurements at the MV side. The new approach can be applied using a proper communication system to collect the nodal measurements and an iterative algorithm based on ladder iterative technique (LIT) to compute the load flow. The validity of this method is presented and discussed on the basis of…
Measurement Issues for the Characterization of Medium Voltage Grids Communications
2013
This paper is focused on the measurement issues and procedures for the characterization of medium voltage grids for narrowband power line communications (NB-PLCs), in the perspective of the use and integration of such technology into smart grids communication networks. The fundamentals are given for the characterization of the PLC channel, by means of noise and attenuation measurements. Suitable procedures are also developed for the characterization and modeling of the power system components in the frequency range of interest. Furthermore, the complete model of the PLC system is experimentally validated in a real case study.
Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication
2013
This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…
Development of a high-accuracy PC-based wattmeter with commercial data acquisition boards
2011
This paper presents the development of a high accuracy sampling wattmeter, which makes use of two commercial data acquisition boards (DAQs) connected to a common personal computer. Commercial software is also used for data processing and implementation of the virtual instrument. The set up of the PC-based wattmeter is described and a preliminary evaluation of its metrological performances is made by means of two series of experimental tests, which were carried out with an electric power standard and a high performance multifunction calibrator. © 2011 IEEE.